Overview
The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. (CWE-732)
Products Affected
Pentaho Business Analytics Server versions before 9.3.0.2 and 9.4.0.1 impacted.
Description
Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2 is installed with a sample HSQLDB data source configured with stored procedures enabled.
Impact
When the vulnerability is leveraged, the attacker can create a malicious stored procedure to write executable JSP files in the application context, leading to remote code execution.
Action
The defect may be mitigated now by deleting the sample HSQLDB database and driver from the product installation.
We recommend you upgrade to Pentaho Business Analytics Server version 9.5 release or newer. For version 9.3, we recommend applying Service Pack 9.3.0.2 or newer. For version 9.4 release we recommend applying Service Pack 9.4.0.1 or newer.
Please review the Pentaho End-of-Life policy to ensure you are up to date.